- Center X
- 167 mm
- Bottom above finished floor
- 430 mm
- Status
- ASSUMPTION
Rescue Modular Eight Heated
Heated four-chamber rescue/community variant for up to eight cats, with a separate product-specific heating zone in each chamber.
Dimensions and construction
- External size
- 2100 × 820 × 760 mm
- Rear height
- 670 mm
- Ground clearance
- 160 mm
- Entrance
- 150 × 180 mm × 4
- Sill above finished floor
- 36 mm
- Chambers
- 4
- Wall thickness
- 71 mm
- Floor assembly
- 74 mm
- Roof assembly
- 71 mm
- Roof vertical projection
- 70.6 mm
- Clear wall height front/rear
- 615 / 525 mm
- Roof angle
- 6.3°
What is actually validated
Status is not promoted because the application looks finished. Each next level requires a new kind of evidence.
fd41682c73a6a388- 01Data and compiler gateCURRENT
DATA_VALIDATEDSchema, sources, assemblies, openings, stock fit, framing/hardware invariants and calculation outputs must remain internally consistent.
- 02Geometry validatedNOT VALIDATED
GEOMETRY_VALIDATEDRequires recorded software and visual verification of 3D/drawings/cut parts, not merely successful data loading.
- 03Engineering reviewNOT VALIDATED
ENGINEERING_REVIEWEDProvisional framing, fastener, moisture, thermal and service details must be reviewed for the actual construction method.
- 04Physical prototypeNOT VALIDATED
PROTOTYPE_BUILTA physical example exists with documented deviations, photographs and a final safety inspection.
- 05Field validationNOT VALIDATED
FIELD_TESTEDThe model has documented real-world use. Even this status is not a universal safe-temperature guarantee.
Transparent thermal estimate
Steady-state envelope transmission estimate. It does not include a validated entrance-infiltration model and is not a temperature guarantee.
This only scales steady-state transmission through wall/floor/roof. ΔT is not an outdoor temperature or guaranteed indoor temperature; infiltration, wind, framing thermal bridges and other effects are not added.
- No validated entrance infiltration model
- No validated airflow model for the provisional ventilation insert zones
- No wind pressure model
- No animal metabolic heat credit
- No transient heat-storage model
- No 2D framing thermal-bridge correction
- No explicit corner/end-grain edge-return thermal-bridge model
Reserved high-rear zones
These are not prescribed vent-opening dimensions. The compiler only reserves zones that avoid provisional framing; the actual cutout and net free area remain specific to the selected adjustable vent insert and physical validation.
- Center X
- 660 mm
- Bottom above finished floor
- 430 mm
- Status
- ASSUMPTION
- Center X
- 1152 mm
- Bottom above finished floor
- 430 mm
- Status
- ASSUMPTION
- Center X
- 1933 mm
- Bottom above finished floor
- 430 mm
- Status
- ASSUMPTION
The zone is a coordination reserve, not proof of adequate ventilation. After construction, condensation, odor/moisture and local drafts must be checked; the actual vent insert or its setting may need adjustment.
Purpose-built heating zones
The compiler reserves one zone in each chamber, but does not specify power, voltage, thermostat behavior or improvised wiring. The selected product must be purpose-built for animals and installed to its own instructions.
- Floor coverage
- 22%
- Unheated choice area
- 0.25 m²
- Position
- X 179 / Z 424 mm
- Floor coverage
- 22%
- Unheated choice area
- 0.25 m²
- Position
- X 672 / Z 424 mm
- Floor coverage
- 22%
- Unheated choice area
- 0.25 m²
- Position
- X 1164 / Z 424 mm
- Floor coverage
- 22%
- Unheated choice area
- 0.25 m²
- Position
- X 1657 / Z 424 mm
Zones are coordination geometry, not an electrical design. Adapters, controllers and unprotected connections do not belong in the animal space. Cable-entry BOM items only reserve protected routing for a selected compatible product.
IEC · IEC 60335-2-71:2018 - Particular requirements for electrical heating appliances for breeding and rearing animals ↗Fabrication materials
Sheet layout
Actual part geometry is shown with a solid outline while the dashed rectangle is the conservative packing envelope. V1 still packs trapezoids by bounding box, so it is not polygon-optimal nesting. Material % measures actual part area; envelope % is the space reserved by the algorithm.
Plywood 12 mm
Plywood 9 mm
XPS insulation
Cost estimate
Quantities come from the model. Prices are not fabricated: enter what you actually pay locally and the estimate stays in your browser.
Sheet, XPS, framing and hardware quantities come from the compiler. The estimate still excludes delivery, tools, labor, local taxes and unforeseen losses beyond the stated allowances. PROVISIONAL and product-specific items remain explicitly labeled.
How to use the model in winter
Construction alone is not enough. Placement, moisture, bedding, weather and routine inspection directly affect real-world shelter performance.
- Place the shelter in a protected location away from direct wind and predator hazards.
- Keep it elevated and dry; the entrance should not sit at wet-ground or snow level.
- For community cats, use straw as winter bedding; towels and blankets can retain moisture.
- Multiple entrances add an escape route but also increase cold-air exchange, making entrance protection more important.
- After snow or heavy rain, check the entrance, bedding dryness and shelter stability.
- Watch for condensation and moisture near the upper zone. The PROVISION ventilation zone is not a predefined opening; the selected insert should be adjusted so it does not create a direct local draft.
Usable interior space
These values are not manually duplicated. The compiler derives them from external dimensions and construction thickness.
Per-animal area and volume are geometric comparison metrics. They are not veterinary, legal or welfare minimums.
Initial cut list
The list includes exterior panels, interior linings, segmented insulation and dividers. Entrance cutouts are derived from the same canonical model.
floor-outerLower floor panelplywood-122100 × 820 × 12 mm1floor-innerInterior floor panelplywood-122100 × 820 × 12 mm1front-outerExterior front panelplywood-12 · Entrance cut-outs are derived from the canonical shelter layout.2100 × 615 × 12 mm1rear-outerExterior rear panelplywood-122100 × 525 × 12 mm1side-outerExterior side panelstrapezoid profile · The side wall fits between the full-width front and rear walls. Clear length 678 mm; front inner edge 608 mm; rear inner edge 533 mm.678 × Hf 608 / Hr 533 × 12 mm2roof-outerExterior roof panelplywood-122240 × 1007 × 12 mm1front-innerInterior front liningplywood-91958 × 608 × 9 mm1rear-innerInterior rear liningplywood-91958 × 533 × 9 mm1side-innerInterior side liningstrapezoid profile · Front clear edge 607.6 mm; rear clear edge 533.2 mm.678 × Hf 608 / Hr 533 × 9 mm2roof-innerInterior roof liningplywood-92100 × 825 × 9 mm1xps-front-r1c1Front-wall XPSxps · Trim entrance openings after dry fitting against the compiled front-panel cutouts.979 × 304 × 50 mm1xps-front-r1c2Front-wall XPSxps · Trim entrance openings after dry fitting against the compiled front-panel cutouts.979 × 304 × 50 mm1xps-front-r2c1Front-wall XPSxps · Trim entrance openings after dry fitting against the compiled front-panel cutouts.979 × 303.6 × 50 mm1xps-front-r2c2Front-wall XPSxps · Trim entrance openings after dry fitting against the compiled front-panel cutouts.979 × 303.6 × 50 mm1xps-rear-r1c1Rear-wall XPSxps979 × 533.2 × 50 mm1xps-rear-r1c2Rear-wall XPSxps979 × 533.2 × 50 mm1xps-side-a-r1c1Side-wall XPS Axps · Final top edge follows the roof slope down to 533.2 mm.678 × 304 × 50 mm1xps-side-a-r2c1Side-wall XPS Axps · Final top edge follows the roof slope down to 533.2 mm.678 × 303.6 × 50 mm1xps-side-b-r1c1Side-wall XPS Bxps · Final top edge follows the roof slope down to 533.2 mm.678 × 304 × 50 mm1xps-side-b-r2c1Side-wall XPS Bxps · Final top edge follows the roof slope down to 533.2 mm.678 × 303.6 × 50 mm1xps-floor-r1c1Floor XPSxps1050 × 410 × 50 mm1xps-floor-r1c2Floor XPSxps1050 × 410 × 50 mm1xps-floor-r2c1Floor XPSxps1050 × 410 × 50 mm1xps-floor-r2c2Floor XPSxps1050 × 410 × 50 mm1xps-roof-r1c1Roof XPSxps1050 × 413 × 50 mm1xps-roof-r1c2Roof XPSxps1050 × 413 × 50 mm1xps-roof-r2c1Roof XPSxps1050 × 412 × 50 mm1xps-roof-r2c2Roof XPSxps1050 × 412 × 50 mm1dividerInterior dividertrapezoid profile · Front clear edge 607.6 mm; rear clear edge 533.2 mm. Cut the top edge to the compiled roof slope.678 × Hf 607.6 / Hr 533.2 × 12 mm3Framing and support schedule
Lengths are derived from model geometry. Frame and base profiles are a V1 design assumption and remain explicitly PROVISIONAL until engineering review and physical validation.
base-runner-1Base runner 1ASSUMPTION · @ 525 mm45 × 45 mm · 820 mm1base-runner-2Base runner 2ASSUMPTION · @ 1050 mm45 × 45 mm · 820 mm1base-runner-3Base runner 3ASSUMPTION · @ 1575 mm45 × 45 mm · 820 mm1base-post-1-1Base support post 1.1ASSUMPTION · X 525 / Z 273 mm45 × 45 mm · 115 mm1base-post-1-2Base support post 1.2ASSUMPTION · X 525 / Z 547 mm45 × 45 mm · 115 mm1base-post-2-1Base support post 2.1ASSUMPTION · X 1050 / Z 273 mm45 × 45 mm · 115 mm1base-post-2-2Base support post 2.2ASSUMPTION · X 1050 / Z 547 mm45 × 45 mm · 115 mm1base-post-3-1Base support post 3.1ASSUMPTION · X 1575 / Z 273 mm45 × 45 mm · 115 mm1base-post-3-2Base support post 3.2ASSUMPTION · X 1575 / Z 547 mm45 × 45 mm · 115 mm1floor-frame-longFloor frame long railsGEOMETRY30 × 50 mm · 820 mm2floor-frame-shortFloor frame cross railsGEOMETRY30 × 50 mm · 2040 mm2front-rear-bottom-railFront/rear lower railsGEOMETRY30 × 50 mm · 2100 mm2front-rear-top-railFront/rear upper railsGEOMETRY30 × 50 mm · 2100 mm2side-bottom-railSide-wall lower railsGEOMETRY30 × 50 mm · 678 mm2side-top-railSloped side-wall upper railsGEOMETRY30 × 50 mm · 682 mm2corner-frontFront corner studsGEOMETRY30 × 50 mm · 615 mm2corner-rearRear corner studsGEOMETRY30 × 50 mm · 525 mm2entrance-1-left-supportEntrance 1 left vertical supportGEOMETRY · @ 236 mm30 × 50 mm · 216 mm1entrance-1-right-supportEntrance 1 right vertical supportGEOMETRY · @ 386 mm30 × 50 mm · 216 mm1entrance-1-headerEntrance 1 headerGEOMETRY · @ 311 mm30 × 50 mm · 210 mm1entrance-1-crippleEntrance 1 cripple studGEOMETRY · @ 311 mm30 × 50 mm · 339 mm1entrance-2-left-supportEntrance 2 left vertical supportGEOMETRY · @ 729 mm30 × 50 mm · 216 mm1entrance-2-right-supportEntrance 2 right vertical supportGEOMETRY · @ 879 mm30 × 50 mm · 216 mm1entrance-2-headerEntrance 2 headerGEOMETRY · @ 804 mm30 × 50 mm · 210 mm1entrance-2-crippleEntrance 2 cripple studGEOMETRY · @ 804 mm30 × 50 mm · 339 mm1entrance-3-left-supportEntrance 3 left vertical supportGEOMETRY · @ 1221 mm30 × 50 mm · 216 mm1entrance-3-right-supportEntrance 3 right vertical supportGEOMETRY · @ 1371 mm30 × 50 mm · 216 mm1entrance-3-headerEntrance 3 headerGEOMETRY · @ 1296 mm30 × 50 mm · 210 mm1entrance-3-crippleEntrance 3 cripple studGEOMETRY · @ 1296 mm30 × 50 mm · 339 mm1entrance-4-left-supportEntrance 4 left vertical supportGEOMETRY · @ 1714 mm30 × 50 mm · 216 mm1entrance-4-right-supportEntrance 4 right vertical supportGEOMETRY · @ 1864 mm30 × 50 mm · 216 mm1entrance-4-headerEntrance 4 headerGEOMETRY · @ 1789 mm30 × 50 mm · 210 mm1entrance-4-crippleEntrance 4 cripple studGEOMETRY · @ 1789 mm30 × 50 mm · 339 mm1divider-cleat-frontFront divider cleatsGEOMETRY30 × 50 mm · 607.6 mm3divider-cleat-rearRear divider cleatsGEOMETRY30 × 50 mm · 533.2 mm3rear-stud-1Rear-wall intermediate studASSUMPTION · @ 420 mm30 × 50 mm · 533.2 mm1rear-stud-2Rear-wall intermediate studASSUMPTION · @ 840 mm30 × 50 mm · 533.2 mm1rear-stud-3Rear-wall intermediate studASSUMPTION · @ 1260 mm30 × 50 mm · 533.2 mm1rear-stud-4Rear-wall intermediate studASSUMPTION · @ 1680 mm30 × 50 mm · 533.2 mm1left-stud-1Side-wall intermediate studASSUMPTION · @ 410 mm30 × 50 mm · 570 mm1right-stud-1Side-wall intermediate studASSUMPTION · @ 410 mm30 × 50 mm · 570 mm1floor-joist-1Floor intermediate joist 1ASSUMPTION · @ 410 mm30 × 50 mm · 2040 mm1roof-rafter-1Roof rafter 1ASSUMPTION · @ 420 mm30 × 50 mm · 825 mm1roof-rafter-2Roof rafter 2ASSUMPTION · @ 840 mm30 × 50 mm · 825 mm1roof-rafter-3Roof rafter 3ASSUMPTION · @ 1260 mm30 × 50 mm · 825 mm1roof-rafter-4Roof rafter 4ASSUMPTION · @ 1680 mm30 × 50 mm · 825 mm1Fasteners, service roof and water
Quantities and geometry are a V1 workshop plan. Fastener spacing uses an APA reference pattern as a conservative starting point, but it is not a certified fastening design for this product.
base-isolation-padsBase isolation pads / feetOne suitable isolation foot or pad below each V1 vertical support so timber does not bear directly on wet ground. Product selection, anchorage and capacity depend on the actual site and substrate.6 pcsASSUMPTIONcorner-weather-trimExterior corner weather trimPlanning length for the four vertical exterior corner edges. Profile, sealing and overlap must be compatible with the selected exterior sheathing and finish system.2.28 mASSUMPTIONpanel-fastenersExterior wood-panel fastenersV1 estimate uses approximately 150 mm edge spacing and 300 mm field spacing as a reference starting pattern. Final diameter, length and schedule remain subject to engineering review.628 pcsASSUMPTIONroof-hingesExterior roof hingesCount is derived from roof width. The hinge axis sits on the front-wall line, inset from the outer front edge by the roof overhang. Verify final hinge type and load capacity before ENGINEERING_REVIEWED status.4 pcsASSUMPTIONroof-latchesRoof latchesIntended to secure the service roof against wind uplift. Latches sit on the rear-wall line, inset from the outer runoff edge by the rear overhang so the exterior drip path remains clear.2 pcsASSUMPTIONroof-edge-weathering-profileRoof edge / drip protectionPlanning length for the full roof-panel perimeter. Final profile, layer order and low rear-edge detail must follow the selected roofing system.6.49 mASSUMPTIONroof-weather-sealService-roof weather sealLength is derived from shelter perimeter; final seal profile depends on the joint detail.5.84 mGEOMETRYprotected-cable-entryProtected cable entryOnly for a purpose-built pet-heating product and its instructions; the app does not specify DIY mains wiring.4 pcsASSUMPTIONBuild sequence
Steps follow the model configuration. Heated variants automatically include a dedicated step constrained to purpose-built equipment.
Build the raised base
Assemble the compiled grid of vertical supports and horizontal runners. Use a suitable isolation foot/pad below each support to keep timber off wet ground; adapt anchorage and bearing details to the actual site.
Assemble the insulated floor
Enclose the insulation between lower and interior floor panels so the animal cannot access it.
Assemble walls to the compiled joinery plan
Front and rear walls remain full width while side walls fit between their inner planes. Use the compiled side lengths/heights and entrance dimensions; do not extend side panels through the corner zones.
Weather-protect the four exterior corner edges
Install compatible exterior corner trim/sealing over the vertical joints so cut panel edges are not exposed to water. The selected trim and overlap must follow the exterior finish system.
Reserve the high-rear ventilation insert zones
Transfer the compiled PROVISIONAL zones to the rear wall and keep them clear of studs. Do not cut the final opening until a specific adjustable vent insert is selected; its cutout and net free area are product-specific.
Install insulation and interior linings
Dry-fit the XPS, enclose it with the interior linings and confirm that no insulation edge is accessible to the animal.
Install interior dividers
Position dividers on the axes between the corresponding entrances, verify stability and seal every sharp edge.
Install roof and waterproofing
The roof falls from front to rear, making the rear edge the natural runoff edge. Select a roofing system that explicitly permits the compiled slope, follow its layer/overlap instructions and detail edge/drip protection so water sheds behind the shelter, away from entrances.
Install a compatible purpose-built heating product
Follow the heating product manufacturer instructions; mains adapters and unprotected connections do not belong in the animal space.
Perform the final safety inspection
Check stability, sharp edges, water ingress, ventilation, entrances and interior dryness.
Sources and limitations
A source supports a method or welfare guideline; it does not turn this specific model into a certified product. Physical validation has a separate status.
Physical validation worksheet
Notes stay only in this browser and are tied to the exact Plan ID. Completing the worksheet does not promote the public model state - it creates an evidence trail for future physical validation.
fd41682c73a6a388This worksheet is not a certificate, veterinary assessment or automatic FIELD_TESTED state. The published validation state changes only after separate review of real evidence.