Interactive 3D model1200 × 700 × 650 mm
Drag to rotate · scroll to zoom
DATA VALIDATED

Nordic Quad Heated

Heated two-chamber variant with space for a compatible purpose-built heating product and an unheated choice zone.

Capacity4
Width1200 mm
Depth700 mm
Insulation50 mm
model v1.0.0compiler v1.8.0plan 52e26d9182a10b4dWINTER SEVEREreference outdoor scenario, not a rating -15 °C
Heating is not a DIY electrical specification. The model requires a compatible purpose-built product installed to its instructions.
Geometry

Dimensions and construction

Compiled drawing sheetNordic Quad Heated
MODELcat-quad-heated-01
VERSIONv1.0.0
STATUSDATA VALIDATED
PLAN ID52e26d9182a10b4d
Compiled technical shelter drawingFront elevation, side elevation, plan and roof panel with dimensions derived from the canonical model.AFRONT ELEVATION + FRAMEB1B2E1E2D11200 mm650 mm140 mm150 mmBSIDE ELEVATION + SLOPESIDE PANEL 558 mmRUNOFF → REARP1P2700 mm650 mm590 mmslope 4.9°CPLAN + CHAMBERSD1HZ1HZ2V1V2E1E21200 mm700 mminternal 1058 × 558 mm · 2 ch.DROOF PANEL + SERVICEHINGE AXIS · FRONT WALL LINELATCHES · REAR WALL LINECLEAR REAR DRIP / RUNOFF EDGEH1H2H3L1L21340 mm884 mmoverhang side 70 mm · front 90 mm · rear 90 mmgeometry frame / axisPROVISIONAL framingdividerhingevent PROVISION zonebase supportheating PROVISION zone
This sheet is compiler-derived. Solid dimensions and chambers are geometry; framing/hardware elements marked PROVISIONAL remain design assumptions until engineering review.
External size
1200 × 700 × 650 mm
Rear height
590 mm
Ground clearance
140 mm
Entrance
150 × 180 mm × 2
Sill above finished floor
36 mm
Chambers
2
Wall thickness
71 mm
Floor assembly
74 mm
Roof assembly
71 mm
Roof vertical projection
70.7 mm
Clear wall height front/rear
505 / 445 mm
Roof angle
4.9°
Validation ladder

What is actually validated

Status is not promoted because the application looks finished. Each next level requires a new kind of evidence.

Current stateDATA VALIDATED
Model versionv1.0.0
Compilerv1.8.0
Plan ID52e26d9182a10b4d
Sources in compiled plan11
  1. 01
    Data and compiler gateDATA_VALIDATED

    Schema, sources, assemblies, openings, stock fit, framing/hardware invariants and calculation outputs must remain internally consistent.

    CURRENT
  2. 02
    Geometry validatedGEOMETRY_VALIDATED

    Requires recorded software and visual verification of 3D/drawings/cut parts, not merely successful data loading.

    NOT VALIDATED
  3. 03
    Engineering reviewENGINEERING_REVIEWED

    Provisional framing, fastener, moisture, thermal and service details must be reviewed for the actual construction method.

    NOT VALIDATED
  4. 04
    Physical prototypePROTOTYPE_BUILT

    A physical example exists with documented deviations, photographs and a final safety inspection.

    NOT VALIDATED
  5. 05
    Field validationFIELD_TESTED

    The model has documented real-world use. Even this status is not a universal safe-temperature guarantee.

    NOT VALIDATED
Thermal

Transparent thermal estimate

Steady-state envelope transmission estimate. It does not include a validated entrance-infiltration model and is not a temperature guarantee.

Wall U · nominal0.55 W/m²K0.50–0.61 W/m²K
Floor U · nominal0.54 W/m²K0.48–0.59 W/m²K
Roof U · nominal0.56 W/m²K0.51–0.62 W/m²K
ΔT comparison20 Kmethod v1.2.0
Nominal envelope transmission38 W34–42 W
Wall Rsi0.13 m²K/Whorizontal heat flow
Roof Rsi0.10 m²K/Wupward heat flow
Floor Rsi0.17 m²K/Wdownward heat flow
Rse0.04 m²K/WISO 6946 · v1.2.0
ΔT explorerScenario temperature difference
20 K
Nominal transmission38 W
Sensitivity band34–42 W

This only scales steady-state transmission through wall/floor/roof. ΔT is not an outdoor temperature or guaranteed indoor temperature; infiltration, wind, framing thermal bridges and other effects are not added.

Current model limitations
  • No validated entrance infiltration model
  • No validated airflow model for the provisional ventilation insert zones
  • No wind pressure model
  • No animal metabolic heat credit
  • No transient heat-storage model
  • No 2D framing thermal-bridge correction
  • No explicit corner/end-grain edge-return thermal-bridge model
Ventilation · PROVISIONAL

Reserved high-rear zones

These are not prescribed vent-opening dimensions. The compiler only reserves zones that avoid provisional framing; the actual cutout and net free area remain specific to the selected adjustable vent insert and physical validation.

StrategyHIGH REAR
Zone per chamber1
Top clearance45 mm
Actual openingTBD by insert
Chamber 1105 × 40 mm
Center X
176 mm
Bottom above finished floor
360 mm
Status
ASSUMPTION
Chamber 2105 × 40 mm
Center X
711 mm
Bottom above finished floor
360 mm
Status
ASSUMPTION
V1 model boundary

The zone is a coordination reserve, not proof of adequate ventilation. After construction, condensation, odor/moisture and local drafts must be checked; the actual vent insert or its setting may need adjustment.

Heating · PRODUCT_SPECIFIC

Purpose-built heating zones

The compiler reserves one zone in each chamber, but does not specify power, voltage, thermostat behavior or improvised wiring. The selected product must be purpose-built for animals and installed to its own instructions.

Chamber 1288 × 223 mm
Floor coverage
22%
Unheated choice area
0.23 m²
Position
X 189 / Z 361 mm
Chamber 2288 × 223 mm
Floor coverage
22%
Unheated choice area
0.23 m²
Position
X 724 / Z 361 mm
No DIY mains heating

Zones are coordination geometry, not an electrical design. Adapters, controllers and unprotected connections do not belong in the animal space. Cable-entry BOM items only reserve protected routing for a selected compatible product.

IEC · IEC 60335-2-71:2018 - Particular requirements for electrical heating appliances for breeding and rearing animals ↗
Fabrication BOM · compiler output

Fabrication materials

Exterior plywood · 12 mm4.75 m²net area of actual cut geometry
Exterior plywood · 9 mm2.33 m²net area of actual cut geometry
XPS insulation · 50 mm3.25 m²net area of actual cut geometry
Sheet planning · deterministic V1

Sheet layout

Actual part geometry is shown with a solid outline while the dashed rectangle is the conservative packing envelope. V1 still packs trapezoids by bounding box, so it is not polygon-optimal nesting. Material % measures actual part area; envelope % is the space reserved by the algorithm.

2500 × 1250 mm · kerf 3 mm · margin 10 mm

Plywood 12 mm

3sheets / boards
Sheet 155% material · 56% envelope
roof-outer-1side-outer-1side-outer-2
Sheet 289% material · 90% envelope
floor-outer-1floor-inner-1front-outer-1rear-outer-1
Sheet 38% material · 9% envelope
divider-1
2500 × 1250 mm · kerf 3 mm · margin 10 mm

Plywood 9 mm

1sheets / boards
Sheet 174% material · 77% envelope
roof-inner-1front-inner-1rear-inner-1side-inner-1side-inner-2
1250 × 600 mm · kerf 2 mm · margin 5 mm

XPS insulation

7sheets / boards
Sheet 156% material · 56% envelope
xps-floor-r1c1-1
Sheet 256% material · 56% envelope
xps-floor-r2c1-1
Sheet 356% material · 56% envelope
xps-roof-r1c1-1
Sheet 456% material · 56% envelope
xps-roof-r2c1-1
Sheet 570% material · 70% envelope
xps-front-r1c1-1
Sheet 664% material · 64% envelope
xps-rear-r1c1-1
Sheet 774% material · 74% envelope
xps-side-a-r1c1-1xps-side-b-r1c1-1
Local price profile

Cost estimate

Quantities come from the model. Prices are not fabricated: enter what you actually pay locally and the estimate stays in your browser.

Plywood 12 mmSheet count from the 2500 × 1250 mm nesting layout.
3 sheetRSD 0
Plywood 9 mmSheet count from the 2500 × 1250 mm nesting layout.
1 sheetRSD 0
XPS 50 mmBoard count from the planning stock size 1250 × 600 mm. Verify dimensions with the local supplier.
7 sheetRSD 0
Roof waterproofingFull sloped roof panel area + 15% allowance for overlap and waste.
1.36 m²RSD 0
Exterior wood protectionExterior wall and floor-underside area + 10% allowance. Coat count and coverage depend on the selected non-toxic exterior product.
2.85 m²RSD 0
Adjustable ventilation insertsOne selected insert for each PROVISION zone. Final cutout and net free area must follow the selected product data sheet.
2 itemRSD 0
Timber framing 30 × 50 mm + base 45 × 45 mmTotal framing schedule length + 10% allowance. Profiles remain PROVISIONAL until engineering review.
23.64 mRSD 0
Base isolation pads / feetOne suitable isolation foot or pad below each V1 vertical support so timber does not bear directly on wet ground. Product selection, anchorage and capacity depend on the actual site and substrate.
4 itemRSD 0
Exterior corner weather trimPlanning length for the four vertical exterior corner edges. Profile, sealing and overlap must be compatible with the selected exterior sheathing and finish system.
1.90 mRSD 0
Exterior wood-panel fastenersV1 estimate uses approximately 150 mm edge spacing and 300 mm field spacing as a reference starting pattern. Final diameter, length and schedule remain subject to engineering review.
367 itemRSD 0
Exterior roof hingesCount is derived from roof width. The hinge axis sits on the front-wall line, inset from the outer front edge by the roof overhang. Verify final hinge type and load capacity before ENGINEERING_REVIEWED status.
3 itemRSD 0
Roof latchesIntended to secure the service roof against wind uplift. Latches sit on the rear-wall line, inset from the outer runoff edge by the rear overhang so the exterior drip path remains clear.
2 itemRSD 0
Roof edge / drip protectionPlanning length for the full roof-panel perimeter. Final profile, layer order and low rear-edge detail must follow the selected roofing system.
4.45 mRSD 0
Service-roof weather sealLength is derived from shelter perimeter; final seal profile depends on the joint detail.
3.80 mRSD 0
Protected cable entryOnly for a purpose-built pet-heating product and its instructions; the app does not specify DIY mains wiring.
2 itemRSD 0
Purpose-built pet heating productPlanning quantity assumes one compatible purpose-built product per compiled heating zone. If a selected certified system explicitly serves multiple zones, actual procurement follows its product data. The app does not design an improvised heater.
2 itemRSD 0
Estimate from entered pricesRSD 0

Sheet, XPS, framing and hardware quantities come from the compiler. The estimate still excludes delivery, tools, labor, local taxes and unforeseen losses beyond the stated allowances. PROVISIONAL and product-specific items remain explicitly labeled.

Operation & welfare

How to use the model in winter

Construction alone is not enough. Placement, moisture, bedding, weather and routine inspection directly affect real-world shelter performance.

  • Place the shelter in a protected location away from direct wind and predator hazards.
  • Keep it elevated and dry; the entrance should not sit at wet-ground or snow level.
  • For community cats, use straw as winter bedding; towels and blankets can retain moisture.
  • Multiple entrances add an escape route but also increase cold-air exchange, making entrance protection more important.
  • After snow or heavy rain, check the entrance, bedding dryness and shelter stability.
  • Watch for condensation and moisture near the upper zone. The PROVISION ventilation zone is not a predefined opening; the selected insert should be adjusted so it does not create a direct local draft.
Compiled geometry

Usable interior space

These values are not manually duplicated. The compiler derives them from external dimensions and construction thickness.

Internal width1058 mm
Internal depth558 mm
Average clear height475 mm
Clear chamber width523 mm
Usable floor area0.58 m²
Approx. usable volume0.28 m³
Per recommended animal0.15 m²
Per max capacity animal0.15 m²

Per-animal area and volume are geometric comparison metrics. They are not veterinary, legal or welfare minimums.

Cut list · compiler output

Initial cut list

The list includes exterior panels, interior linings, segmented insulation and dividers. Entrance cutouts are derived from the same canonical model.

IDPartDimensionsQty
floor-outerLower floor panelplywood-121200 × 700 × 12 mm1
floor-innerInterior floor panelplywood-121200 × 700 × 12 mm1
front-outerExterior front panelplywood-12 · Entrance cut-outs are derived from the canonical shelter layout.1200 × 505 × 12 mm1
rear-outerExterior rear panelplywood-121200 × 445 × 12 mm1
side-outerExterior side panelstrapezoid profile · The side wall fits between the full-width front and rear walls. Clear length 558 mm; front inner edge 499 mm; rear inner edge 451 mm.558 × Hf 499 / Hr 451 × 12 mm2
roof-outerExterior roof panelplywood-121340 × 884 × 12 mm1
front-innerInterior front liningplywood-91058 × 499 × 9 mm1
rear-innerInterior rear liningplywood-91058 × 451 × 9 mm1
side-innerInterior side liningstrapezoid profile · Front clear edge 499.2 mm; rear clear edge 451.3 mm.558 × Hf 499 / Hr 451 × 9 mm2
roof-innerInterior roof liningplywood-91200 × 703 × 9 mm1
xps-front-r1c1Front-wall XPSxps · Trim entrance openings after dry fitting against the compiled front-panel cutouts.1058 × 499.2 × 50 mm1
xps-rear-r1c1Rear-wall XPSxps1058 × 451.3 × 50 mm1
xps-side-a-r1c1Side-wall XPS Axps · Final top edge follows the roof slope down to 451.3 mm.558 × 499.2 × 50 mm1
xps-side-b-r1c1Side-wall XPS Bxps · Final top edge follows the roof slope down to 451.3 mm.558 × 499.2 × 50 mm1
xps-floor-r1c1Floor XPSxps1200 × 350 × 50 mm1
xps-floor-r2c1Floor XPSxps1200 × 350 × 50 mm1
xps-roof-r1c1Roof XPSxps1200 × 352 × 50 mm1
xps-roof-r2c1Roof XPSxps1200 × 351 × 50 mm1
dividerInterior dividertrapezoid profile · Front clear edge 499.2 mm; rear clear edge 451.3 mm. Cut the top edge to the compiled roof slope.558 × Hf 499.2 / Hr 451.3 × 12 mm1
Framing · PROVISIONAL

Framing and support schedule

Lengths are derived from model geometry. Frame and base profiles are a V1 design assumption and remain explicitly PROVISIONAL until engineering review and physical validation.

Frame profile30 × 50 mm
Base profile45 × 45 mm
Base runners2
Base support posts4
Support post height95 mm
Max wall stud spacing≈ 500 mm
Max floor joist spacing≈ 500 mm
Max roof rafter spacing≈ 500 mm
Max runner spacing≈ 700 mm
Max support-row spacing≈ 700 mm
Total linear length21.5 m
IDMemberProfile × lengthQty
base-runner-1Base runner 1ASSUMPTION · @ 400 mm45 × 45 mm · 700 mm1
base-runner-2Base runner 2ASSUMPTION · @ 800 mm45 × 45 mm · 700 mm1
base-post-1-1Base support post 1.1ASSUMPTION · X 400 / Z 233 mm45 × 45 mm · 95 mm1
base-post-1-2Base support post 1.2ASSUMPTION · X 400 / Z 467 mm45 × 45 mm · 95 mm1
base-post-2-1Base support post 2.1ASSUMPTION · X 800 / Z 233 mm45 × 45 mm · 95 mm1
base-post-2-2Base support post 2.2ASSUMPTION · X 800 / Z 467 mm45 × 45 mm · 95 mm1
floor-frame-longFloor frame long railsGEOMETRY30 × 50 mm · 700 mm2
floor-frame-shortFloor frame cross railsGEOMETRY30 × 50 mm · 1140 mm2
front-rear-bottom-railFront/rear lower railsGEOMETRY30 × 50 mm · 1200 mm2
front-rear-top-railFront/rear upper railsGEOMETRY30 × 50 mm · 1200 mm2
side-bottom-railSide-wall lower railsGEOMETRY30 × 50 mm · 558 mm2
side-top-railSloped side-wall upper railsGEOMETRY30 × 50 mm · 560 mm2
corner-frontFront corner studsGEOMETRY30 × 50 mm · 505 mm2
corner-rearRear corner studsGEOMETRY30 × 50 mm · 445 mm2
entrance-1-left-supportEntrance 1 left vertical supportGEOMETRY · @ 258 mm30 × 50 mm · 216 mm1
entrance-1-right-supportEntrance 1 right vertical supportGEOMETRY · @ 408 mm30 × 50 mm · 216 mm1
entrance-1-headerEntrance 1 headerGEOMETRY · @ 333 mm30 × 50 mm · 210 mm1
entrance-1-crippleEntrance 1 cripple studGEOMETRY · @ 333 mm30 × 50 mm · 229 mm1
entrance-2-left-supportEntrance 2 left vertical supportGEOMETRY · @ 793 mm30 × 50 mm · 216 mm1
entrance-2-right-supportEntrance 2 right vertical supportGEOMETRY · @ 943 mm30 × 50 mm · 216 mm1
entrance-2-headerEntrance 2 headerGEOMETRY · @ 868 mm30 × 50 mm · 210 mm1
entrance-2-crippleEntrance 2 cripple studGEOMETRY · @ 868 mm30 × 50 mm · 229 mm1
divider-cleat-frontFront divider cleatsGEOMETRY30 × 50 mm · 499.2 mm1
divider-cleat-rearRear divider cleatsGEOMETRY30 × 50 mm · 451.3 mm1
rear-stud-1Rear-wall intermediate studASSUMPTION · @ 400 mm30 × 50 mm · 451.3 mm1
rear-stud-2Rear-wall intermediate studASSUMPTION · @ 800 mm30 × 50 mm · 451.3 mm1
left-stud-1Side-wall intermediate studASSUMPTION · @ 350 mm30 × 50 mm · 475 mm1
right-stud-1Side-wall intermediate studASSUMPTION · @ 350 mm30 × 50 mm · 475 mm1
floor-joist-1Floor intermediate joist 1ASSUMPTION · @ 350 mm30 × 50 mm · 1140 mm1
roof-rafter-1Roof rafter 1ASSUMPTION · @ 400 mm30 × 50 mm · 703 mm1
roof-rafter-2Roof rafter 2ASSUMPTION · @ 800 mm30 × 50 mm · 703 mm1
Hardware · PROVISIONAL

Fasteners, service roof and water

Quantities and geometry are a V1 workshop plan. Fastener spacing uses an APA reference pattern as a conservative starting point, but it is not a certified fastening design for this product.

Edge spacing≈ 150 mm
Field spacing≈ 300 mm
Panel joint gap3 mm
Roof slope4.9°
Runoff edgerear
Rear drip edge1.34 m
Hinge axis from front edge90 mm
Latch axis from front edge793 mm
IDItemQuantityStatus
base-isolation-padsBase isolation pads / feetOne suitable isolation foot or pad below each V1 vertical support so timber does not bear directly on wet ground. Product selection, anchorage and capacity depend on the actual site and substrate.4 pcsASSUMPTION
corner-weather-trimExterior corner weather trimPlanning length for the four vertical exterior corner edges. Profile, sealing and overlap must be compatible with the selected exterior sheathing and finish system.1.90 mASSUMPTION
panel-fastenersExterior wood-panel fastenersV1 estimate uses approximately 150 mm edge spacing and 300 mm field spacing as a reference starting pattern. Final diameter, length and schedule remain subject to engineering review.367 pcsASSUMPTION
roof-hingesExterior roof hingesCount is derived from roof width. The hinge axis sits on the front-wall line, inset from the outer front edge by the roof overhang. Verify final hinge type and load capacity before ENGINEERING_REVIEWED status.3 pcsASSUMPTION
roof-latchesRoof latchesIntended to secure the service roof against wind uplift. Latches sit on the rear-wall line, inset from the outer runoff edge by the rear overhang so the exterior drip path remains clear.2 pcsASSUMPTION
roof-edge-weathering-profileRoof edge / drip protectionPlanning length for the full roof-panel perimeter. Final profile, layer order and low rear-edge detail must follow the selected roofing system.4.45 mASSUMPTION
roof-weather-sealService-roof weather sealLength is derived from shelter perimeter; final seal profile depends on the joint detail.3.80 mGEOMETRY
protected-cable-entryProtected cable entryOnly for a purpose-built pet-heating product and its instructions; the app does not specify DIY mains wiring.2 pcsASSUMPTION
Roof weathering gateOwens Corning Roofing · Oakridge and TruDefinition Duration Oakridge Shingles Installation Instructions ↗The compiled slope defines geometry, but the selected roofing product must explicitly permit that slope and define layers, overlaps, fastening and edge details.
Build sequence

Build sequence

Steps follow the model configuration. Heated variants automatically include a dedicated step constrained to purpose-built equipment.

0 / 10steps completed
  1. Build the raised base

    Assemble the compiled grid of vertical supports and horizontal runners. Use a suitable isolation foot/pad below each support to keep timber off wet ground; adapt anchorage and bearing details to the actual site.

  2. Assemble the insulated floor

    Enclose the insulation between lower and interior floor panels so the animal cannot access it.

  3. Assemble walls to the compiled joinery plan

    Front and rear walls remain full width while side walls fit between their inner planes. Use the compiled side lengths/heights and entrance dimensions; do not extend side panels through the corner zones.

  4. Weather-protect the four exterior corner edges

    Install compatible exterior corner trim/sealing over the vertical joints so cut panel edges are not exposed to water. The selected trim and overlap must follow the exterior finish system.

  5. Reserve the high-rear ventilation insert zones

    Transfer the compiled PROVISIONAL zones to the rear wall and keep them clear of studs. Do not cut the final opening until a specific adjustable vent insert is selected; its cutout and net free area are product-specific.

  6. Install insulation and interior linings

    Dry-fit the XPS, enclose it with the interior linings and confirm that no insulation edge is accessible to the animal.

  7. Install interior dividers

    Position dividers on the axes between the corresponding entrances, verify stability and seal every sharp edge.

  8. Install roof and waterproofing

    The roof falls from front to rear, making the rear edge the natural runoff edge. Select a roofing system that explicitly permits the compiled slope, follow its layer/overlap instructions and detail edge/drip protection so water sheds behind the shelter, away from entrances.

  9. Install a compatible purpose-built heating product

    Follow the heating product manufacturer instructions; mains adapters and unprotected connections do not belong in the animal space.

  10. Perform the final safety inspection

    Check stability, sharp edges, water ingress, ventilation, entrances and interior dryness.

Provenance

Sources and limitations

A source supports a method or welfare guideline; it does not turn this specific model into a certified product. Physical validation has a separate status.

ASPCApro · Tier 1Winter Shelters for Community Cats: FAQs and Cold Weather TipsSupports small insulated shelters, cat-sized entrances, elevation from wet ground, straw bedding and predator-aware entrance decisions.ASPCA · Tier 1Cold Weather Safety TipsSupports the limitation that outdoor auxiliary shelters are not a substitute for keeping companion animals indoors during severe cold.ISO · Tier 1ISO 6946:2017 - Thermal resistance and thermal transmittance - Calculation methodsMethodological reference for steady-state layer resistance and transmittance. Thermal method v1.1 applies orientation-specific internal surface resistances: Rsi 0.10 m²K/W for upward heat flow, 0.13 for horizontal and 0.17 for downward, with Rse 0.04 m²K/W. The app does not claim ISO certification.ISO · Tier 1ISO 13789:2017 - Transmission and ventilation heat transfer coefficientsMethodological reference for separating transmission and ventilation heat transfer. The MVP does not claim a validated infiltration model.IEC · Tier 1IEC 60335-2-71:2018 - Particular requirements for electrical heating appliances for breeding and rearing animalsSafety reference for electrical animal-heating appliances. The app only accommodates purpose-built products and does not claim product certification.Nord Compensati · Tier 2Technical Specifications of Birch Marine PlywoodManufacturer technical specification lists thermal conductivity of 0.17 W/mK for birch marine plywood.USDA Forest Products Laboratory · Tier 1Wood Handbook: Wood as an Engineering Material, Chapter 4Documents that wood thermal conductivity varies materially with species, density, moisture content and grain direction.ISO · Tier 1ISO 10456:2007 - Hygrothermal properties - Declared and design thermal valuesCurrent published edition, confirmed in 2023; provides procedures for declared/design thermal values and conversion for temperature and moisture conditions.FIBRAN · Tier 1FIBRANxps 300 Technical Data SheetDeclares 1250 × 600 mm board dimensions and λD 0.033 W/mK for thicknesses up to 60 mm.APA - The Engineered Wood Association · Tier 1Builder Tips: Proper Installation of APA Rated Sheathing for Roof Applications (N335)Reference starting point for panel fastening geometry: approximately 6 in edge spacing, 12 in intermediate spacing and about 3/8 in edge offset. Šapice does not treat this roof-sheathing guide as a certified fastening design for pet shelters.Owens Corning Roofing · Tier 1Oakridge and TruDefinition Duration Oakridge Shingles Installation InstructionsManufacturer example showing that low-slope roof assemblies require slope-specific underlayment/edge details. Šapice uses this as evidence that final roof covering compatibility must follow the selected product instructions, not as a universal shelter roofing specification.
Prototype evidence · local only

Physical validation worksheet

Notes stay only in this browser and are tied to the exact Plan ID. Completing the worksheet does not promote the public model state - it creates an evidence trail for future physical validation.

MODELcat-quad-heated-01
MODEL VERSIONv1.0.0
COMPILERv1.8.0
PLAN ID52e26d9182a10b4d
Recorded checks0 / 10

This worksheet is not a certificate, veterinary assessment or automatic FIELD_TESTED state. The published validation state changes only after separate review of real evidence.