Design class: BudgetValidation status: Data validated

Pallet + OSB Dog House

The same pallet frame as the basic version, with EPS in the cavities, OSB cladding outside and an interior lining. Floor and roof are not insulated.

This is an auxiliary outdoor shelter. During dangerous cold or heat give the dog a safe indoor space.

“Data validated” means only the data and calculations are checked; the model has not been built or tested physically.

Dog sizemedium
Outside size1200 × 812
BuildIntermediate
Time (estimate)6 h–10 h
model v1.0.0compiler P1.0.0plan 2e3615de20278e42Pallet frameWinter · Rain · Wind
1200 mm

This model has no 3D view; the drawing and dimensions below fully describe the construction.

Who this is for
  • For beginners with basic tools and a small budget.
  • For one medium dog as an auxiliary outdoor solution; measure the dog before building.
When not to use it
  • At a fully exposed spot: it needs shelter from wind and rain (a wall, fence or eaves).
  • As a substitute for being indoors during dangerous cold or heat.
  • For young, old, sick or unacclimated animals without extra protection and supervision.
Tools and calculations
Required tools
Hand saw, Jigsaw +1
Budget class
Low
Location
Sheltered outdoor spot
Supported calculations
Geometry, Bill of materials, Cut list, Sheet nesting, Cost estimate, Drawing, Build guide
Build time is a planning estimate, not a promise.
Geometry

Dimensions

Front, side and top views. Outside size 1200 × 812 mm, front height 1079 mm, rear 1019 mm.A · FRONT VIEWB · SIDE VIEWC · PLAN1200 mm1223 mmwater runs off to the rear →812 mm1163 mm1200 mminside 894 × 647 × 791 mm
Text equivalent of the drawing
Outside size (W × D)1200 × 812 mm
Height front / rear1079 / 1019 mm
Raised off the ground144 mm
Interior894 × 647 × 791 mm
Entrance1 × 400 × 600 mm, sill 0 mm
Chambers1
Geometry typederived from canonical dimensions
Bill of materials · compiler output

What you have and what to obtain

Quantities come from the model geometry; items marked as assumptions are planning allowances. Reused material must pass the checklist.

Fill in “My workshop” to see what you still need to buy.

My workshop
MaterialNeededOwnedStatus
EPS foam board10 sheets–Buy
OSB/3 board2 sheets–Buy
OSB/3 board1 sheets–Buy
Interior plywood lining2 sheets–Buy
Solid softwood (battens, studs)6.92 m–Buy
Wooden pallet4 pcs–Buy
Bituminous membrane1.73 m²–Buy
Wood screws2 pack–Buy
Sealant1 pack–Buy
Straw1 bale–Buy
  • EPS foam board10 sheetssheet nesting · 10 × 1000 × 500 mm (planning format; check with your supplier).
  • OSB/3 board2 sheetssheet nesting · 2 × 2500 × 1250 mm (planning format; check with your supplier).
  • OSB/3 board1 sheetssheet nesting · 1 × 2500 × 1250 mm (planning format; check with your supplier).
  • Interior plywood lining2 sheetssheet nesting · 2 × 2500 × 1250 mm (planning format; check with your supplier).
  • Solid softwood (battens, studs)6.92 mfrom geometry · Total length from the cut list + 10% allowance.
  • Wooden pallet4 pcsfrom geometry · Number of distinct pallets the sections are cut from; each must pass the checklist.
  • Bituminous membrane1.73 m²assumption · Roof area + 15% for overlaps.
  • Wood screws2 packassumption · Joining pallets and cladding; tips must not protrude inside.
  • Sealant1 packassumption · Exterior roof joints.
  • Straw1 baleassumption · Loosely to a quarter or half of the height; keep the rest dry for refills.
Cut list

Parts to cut

IDPartDimensionsQty
pallet-floor-1Pallet section (floor) from pallet 1Each cut must leave a stringer or block at its end; adapt to the real pallet.1200 × 800 × 144 mm1
pallet-back-2Pallet section (back) from pallet 2Each cut must leave a stringer or block at its end; adapt to the real pallet.1200 × 800 × 144 mm1
pallet-side_left-3Pallet section (side left) from pallet 3Each cut must leave a stringer or block at its end; adapt to the real pallet.800 × 800 × 144 mm1
pallet-front_left-4Pallet section (front left) from pallet 3Each cut must leave a stringer or block at its end; adapt to the real pallet.400 × 800 × 144 mm1
pallet-side_right-5Pallet section (side right) from pallet 4Each cut must leave a stringer or block at its end; adapt to the real pallet.800 × 800 × 144 mm1
pallet-front_right-6Pallet section (front right) from pallet 4Each cut must leave a stringer or block at its end; adapt to the real pallet.400 × 800 × 144 mm1
roofRoof · OSB/3 board1360 × 1106 × 15 mm1
clad-backOuter cladding (back) · OSB/3 board1200 × 800 × 12 mm1
clad-sideOuter cladding (side) · OSB/3 board800 × 800 × 12 mm2
clad-front-1Outer cladding (front-1) · OSB/3 board400 × 800 × 12 mm1
clad-front-2Outer cladding (front-2) · OSB/3 board400 × 800 × 12 mm1
ins-back-r1c1Pallet cavity insulation (back) · EPS foam boardSegment 1/2, 1/2; butt-join.600 × 400 × 50 mm1
ins-back-r1c2Pallet cavity insulation (back) · EPS foam boardSegment 1/2, 2/2; butt-join.600 × 400 × 50 mm1
ins-back-r2c1Pallet cavity insulation (back) · EPS foam boardSegment 2/2, 1/2; butt-join.600 × 400 × 50 mm1
ins-back-r2c2Pallet cavity insulation (back) · EPS foam boardSegment 2/2, 2/2; butt-join.600 × 400 × 50 mm1
ins-side-r1c1Pallet cavity insulation (side) · EPS foam boardSegment 1/2, 1/1; butt-join.800 × 400 × 50 mm2
ins-side-r2c1Pallet cavity insulation (side) · EPS foam boardSegment 2/2, 1/1; butt-join.800 × 400 × 50 mm2
ins-front-1Pallet cavity insulation (front-1) · EPS foam boardCut to fit between the pallet stringers.400 × 800 × 50 mm1
ins-front-2Pallet cavity insulation (front-2) · EPS foam boardCut to fit between the pallet stringers.400 × 800 × 50 mm1
lin-backInterior lining (back) · Interior plywood lining1200 × 800 × 9 mm1
lin-sideInterior lining (side) · Interior plywood lining800 × 800 × 9 mm2
lin-front-1Interior lining (front-1) · Interior plywood lining400 × 800 × 9 mm1
lin-front-2Interior lining (front-2) · Interior plywood lining400 × 800 × 9 mm1
lin-floorInterior lining (floor) · Interior plywood lining1200 × 800 × 9 mm1
roof-fall-battenTapered roof-fall batten38 × 60 mm · 944 mm2
front-headerHeader board above the entrance24 × 100 mm · 1200 mm1
corner-tiesCorner tie battens38 × 38 mm · 800 mm4
Sheet nesting

Parts on sheets

Sheet formats are planning assumptions; check your supplier's format. Sloped parts occupy their rectangular envelope.

EPS foam board · 50 mm10 × 1000 × 500 mm

ins-side-r1c1
Sheet 1 · 64% used
ins-side-r1c1
Sheet 2 · 64% used
ins-side-r2c1
Sheet 3 · 64% used
ins-side-r2c1
Sheet 4 · 64% used
ins-front-1
Sheet 5 · 64% used
ins-front-2
Sheet 6 · 64% used
ins-back-r1c1
Sheet 7 · 48% used
ins-back-r1c2
Sheet 8 · 48% used
ins-back-r2c1
Sheet 9 · 48% used
ins-back-r2c2
Sheet 10 · 48% used

OSB/3 board · 12 mm2 × 2500 × 1250 mm

clad-backclad-sideclad-side
Sheet 1 · 72% used
clad-front-1clad-front-2
Sheet 2 · 20% used

OSB/3 board · 15 mm1 × 2500 × 1250 mm

roof
Sheet 1 · 48% used

Interior plywood lining · 9 mm2 × 2500 × 1250 mm

lin-backlin-floorlin-side
Sheet 1 · 82% used
lin-sidelin-front-1lin-front-2
Sheet 2 · 41% used
Layers and thermal

Known and unknown layers

Partial estimate: some layers are unknown, so no U-value is calculated. Only the resistance of known layers is shown.

Wall

  • OSB/3 board · 12 mmR 0.09
  • EPS foam board · 50 mmR 1.32
  • Interior plywood lining · 9 mmR 0.05
  • Wooden pallet · 144 mm (assumed)unknown

Known-layer resistance: 1.46 m²K/W

Not included
  • Air leakage through the entrance and joints
  • Thermal bridges through battens, edges and fasteners
  • Moisture, condensation and property changes of damp material
  • Heat produced by the animal
  • Wind and transient temperature changes
Assumptions
  • Thin layers without a sourced λ (roof covering, film, mat) are not counted.
  • The pallet is an unknown layer with voids; only known layers are counted.
  • Floor and roof are not insulated.

The estimate is not a temperature guarantee and does not claim the shelter is safe to any temperature.

Water and moisture

Weather exposure

A warm shelter that gets damp can be worse than a simpler one that stays dry. This is an explanation, not a condensation calculation.

  • Ground contactRaised about 144 mm off the ground.
  • Rain splashHigh enough that rain splash from the ground does not hit the floor.
  • Roof drainageThe roof falls from the entrance to the rear, so water runs off away from the entrance.
  • Rain at the entranceLow sill: rain and snow get in more easily; turn the entrance away from wind.
  • DryingWithout a service opening drying and cleaning are harder; change bedding through the entrance.
  • Absorbent materialThe material absorbs moisture; check it more often and replace it when damp.
  • Maintenance accessLeave room around the house for checks and cleaning.
Local price profile

Cost estimate

Quantities come from the model. Prices are not fabricated: enter what you actually pay locally and the estimate stays in your browser.

Prices entered: 0 / 10
EPS foam board10 × 1000 × 500 mm (planning format; check with your supplier).
10 sheetsRSD 0
OSB/3 board2 × 2500 × 1250 mm (planning format; check with your supplier).
2 sheetsRSD 0
OSB/3 board1 × 2500 × 1250 mm (planning format; check with your supplier).
1 sheetRSD 0
Interior plywood lining2 × 2500 × 1250 mm (planning format; check with your supplier).
2 sheetsRSD 0
Solid softwood (battens, studs)Total length from the cut list + 10% allowance.
6.92 mRSD 0
Wooden palletNumber of distinct pallets the sections are cut from; each must pass the checklist.
4 itemsRSD 0
Bituminous membraneRoof area + 15% for overlaps.
1.73 m²RSD 0
Wood screwsJoining pallets and cladding; tips must not protrude inside.
2 itemsRSD 0
SealantExterior roof joints.
1 itemRSD 0
StrawLoosely to a quarter or half of the height; keep the rest dry for refills.
1 itemRSD 0
Estimate from entered pricesRSD 0

Sheet, XPS, framing and hardware quantities come from the compiler. The estimate still excludes delivery, tools, labor, local taxes and unforeseen losses beyond the stated allowances. PROVISIONAL and product-specific items remain explicitly labeled.

Placement

Check the spot

Tick what applies to the chosen spot
No obvious issue detected

This is not a safety certificate for the spot: it only means none of the listed questions is ticked.

Bedding

What goes inside

Maintenance

Inspection schedule

  • WeeklyCheck that the straw is dry and loose; replace it when damp or compacted.
  • WeeklyCheck for water or dampness on the floor and walls, especially under the entrance.
  • After stormsAfter rain or snow check the interior and the ground under the shelter.
  • MonthlyCheck the roof covering, overlaps and that water runs off at the rear, away from the entrance.
  • MonthlyCheck that screws and nails are tight and no tip protrudes.
  • MonthlyCheck edges: no splinters, cracks or swollen areas.
  • After stormsClear snow from entrances and exits so the animal cannot be snowed in.
  • Each seasonClean the interior; service access must allow cleaning without dismantling.
Upgrade path

Where to go next

Each step states what you add, what you gain and what stays limited. A new model has a new plan ID; changing an existing build has no canonical plan.

Previous step: Pallet Basic Dog House

In-place changeInsulated roof: XPS under the roof board with a lining.
You add
Insulated roof: XPS under the roof board with a lining.
You gain
Less heat loss through the roof.
Still limited
A change to your build; the thermal estimate does not follow the change.
New material
XPS foam board, Interior plywood lining
New model · new plan IDOSB Economy Dog House Medium →
You add
A panel box with insulated floor and roof.
You gain
A complete thermal estimate and less origin checking.
Still limited
Buying boards.
New material
OSB/3 board, EPS foam board, Interior plywood lining

Don't have this material?

EPS foam board · 50 mm
  • XPS foam boardabout the same layer resistance at 44 mm (conservatively 49 mm); thermal equivalence is not structural
  • PIR / polyiso boardabout the same layer resistance at 32 mm; thermal equivalence is not structural
  • Cork boardPossible substitute requiring redesign: at least one material has no sourced thermal conductivity, so an equivalent thickness cannot be calculated.
OSB/3 board · 15 mm
  • OSB/4 boardThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • Exterior plywoodThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
Interior plywood lining · 9 mm
  • Exterior plywoodThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • OSB/3 boardThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • Vinyl protective floor surfaceThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
Wooden pallet · 144 mm
  • Scrap lumber and old boardsThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • OSB/3 boardThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
Bituminous membrane
  • EPDM membraneThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • Roofing feltThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
  • Galvanized sheet metalThe substitute changes the construction (thickness, strength or water protection); parts and joints must be re-planned.
All substitutes and material limits
Build sequence

Build steps

Progress is stored in this browser against the exact plan ID; it works offline once the page has been opened.

0 / 9steps completed
  1. Inspect the pallets

    Every pallet must pass the checklist: no stains, chemical smell, oil, rot or mould. An ISPM 15 mark confirms only a phytosanitary treatment, not the pallet's history.

  2. Cut the pallet sections

    Cut sections per the cut list so a stringer or block remains at each end. Remove protruding nails and sand the edges.

  3. Assemble the frame

    Set the floor pallet level, fix the back and side sections onto it and tie the corners with battens. The front sections leave the entrance opening.

  4. Insulate the cavities

    Cut insulation boards to fit between the pallet stringers and place them in the wall cavities.

  5. Close the gaps outside

    Fix cladding on the outside so wind and rain cannot pass through the gaps between boards.

  6. Interior lining

    Fit an interior lining so the animal touches neither insulation nor rough pallet parts.

  7. Roof falling to the rear

    Fit two tapered battens so the roof falls 60 mm to the rear, then fix the roof board and covering. Water must run off behind the house, away from the entrance.

  8. Add straw, not hay

    Loosely fill straw to a quarter or half of the interior height. Do not use hay, towels or blankets in an outdoor winter shelter: they absorb moisture and chill.

  9. Choose the spot and secure it

    Set it against a wall or fence, out of the wind, away from roof runoff and roaming dogs. Weight or secure lightweight shelters. Check the spot with the placement checklist.

Provenance

Sources and verification status

A source supports a guideline or material value, but it does not confirm this specific model. Container sizes are assumptions and build time is a planning estimate.

  1. Data validatedcurrent
  2. Geometry validatednot confirmed
  3. Engineering reviewnot confirmed
  4. Physical prototypenot confirmed
  5. Field validationnot confirmed
International Plant Protection Convention (IPPC) · Tier 1ISPM 15: Regulation of wood packaging material in international tradePhytosanitary standard for wood packaging in international trade, including treatment codes such as HT (heat treatment) and MB (methyl bromide). The mark confirms a phytosanitary treatment only; it says nothing about the later history, contamination or condition of a used pallet.U.S. Environmental Protection Agency · Tier 1Chromated Arsenicals (CCA)CCA-treated wood was withdrawn from US homeowner uses at the end of 2003, but older structures may still contain it. Do not burn it; use dust protection when sawing and wash hands after handling. Šapice therefore rejects unknown old treated timber wherever an animal could chew or lick it.Humane World for Animals · Tier 1How to Keep Pets Warm in Cold WeatherEmphasizes indoor shelter when possible; when a dog must be outside, shelter should be dry, draft-free, raised and appropriately sized.ISO · Tier 1ISO 10456:2007 - Hygrothermal properties - Declared and design thermal valuesCurrent published edition, confirmed in 2023; provides procedures for declared/design thermal values and conversion for temperature and moisture conditions.U.S. DOE Building America Solution Center (PNNL) · Tier 1Typical R-Values and Vapor Retarder Classifications of Common Insulation MaterialsTypical R-value per inch: EPS 3.8-4.4, XPS 5, polyiso approx. 6, fiberglass batt or board 2.5-4, mineral wool board 3-4. Šapice converts these to planning λ ranges (λ = 0.0254 m / (R_IP × 0.1761)); a product datasheet always takes precedence.USDA Forest Products Laboratory · Tier 1Wood Handbook: Wood as an Engineering Material, Chapter 4Documents that wood thermal conductivity varies materially with species, density, moisture content and grain direction.