Wall
- OSB/3 board · 9 mmR 0.07
- EPS foam board · 30 mmR 0.79
- Interior plywood lining · 4 mmR 0.02
Known-layer resistance: 0.88 m²K/W · U 0.95 W/m²K
A lighter insulated box without roof covering, only for a porch, shed or garage with no rain. It must not stand outside without a roof.
A warm shelter that gets damp can be worse than a simpler one that stays dry.
“Data validated” means only the data and calculations are checked; the model has not been built or tested physically.
This model has no 3D view; the drawing and dimensions below fully describe the construction.
| Outside size (W × D) | 700 × 550 mm |
|---|---|
| Height front / rear | 480 / 440 mm |
| Raised off the ground | 50 mm |
| Interior | 614 × 464 × 374 mm |
| Entrance | 1 × 150 × 180 mm, sill 80 mm |
| Chambers | 1 |
| Geometry type | derived from canonical dimensions |
Quantities come from the model geometry; items marked as assumptions are planning allowances. Reused material must pass the checklist.
Fill in “My workshop” to see what you still need to buy.
My workshopshell-floorFloor · OSB/3 board700 × 550 × 9 mm1shell-frontFront wall · OSB/3 board700 × 462 × 9 mm1shell-rearRear wall · OSB/3 board700 × 422 × 9 mm1shell-sideSide wall · OSB/3 boardsloped top edge532 × 461/423 × 9 mm2shell-roofRoof · OSB/3 board720 × 571 × 9 mm1ins-floor-r1c1Floor insulation · EPS foam boardSegment 1/2, 1/1; butt-join.682 × 266 × 30 mm1ins-floor-r2c1Floor insulation · EPS foam boardSegment 2/2, 1/1; butt-join.682 × 266 × 30 mm1ins-frontFront wall insulation · EPS foam board682 × 428 × 30 mm1ins-rearRear wall insulation · EPS foam board682 × 388 × 30 mm1ins-sideSide wall insulation · EPS foam boardsloped top edge472 × 425/391 × 30 mm2ins-roofRoof insulation · EPS foam board614 × 465 × 30 mm1lin-floorFloor lining · Interior plywood lining682 × 532 × 4 mm1lin-frontFront wall lining · Interior plywood lining622 × 428 × 4 mm1lin-rearRear wall lining · Interior plywood lining622 × 388 × 4 mm1lin-sideSide wall lining · Interior plywood liningsloped top edge464 × 425/391 × 4 mm2lin-roofRoof lining · Interior plywood lining614 × 465 × 4 mm1corner-batten-frontFront corner batten38 × 38 mm · 462 mm2corner-batten-rearRear corner batten38 × 38 mm · 422 mm2raise-battenRaising batten45 × 50 mm · 550 mm2Sheet formats are planning assumptions; check your supplier's format. Sloped parts occupy their rectangular envelope.
Complete estimate: every layer has a sourced thermal conductivity.
Known-layer resistance: 0.88 m²K/W · U 0.95 W/m²K
Known-layer resistance: 0.88 m²K/W · U 0.92 W/m²K
Known-layer resistance: 0.88 m²K/W · U 0.98 W/m²K
The estimate is not a temperature guarantee and does not claim the shelter is safe to any temperature.
A warm shelter that gets damp can be worse than a simpler one that stays dry. This is an explanation, not a condensation calculation.
Quantities come from the model. Prices are not fabricated: enter what you actually pay locally and the estimate stays in your browser.
Sheet, XPS, framing and hardware quantities come from the compiler. The estimate still excludes delivery, tools, labor, local taxes and unforeseen losses beyond the stated allowances. PROVISIONAL and product-specific items remain explicitly labeled.
This is not a safety certificate for the spot: it only means none of the listed questions is ticked.
Each step states what you add, what you gain and what stays limited. A new model has a new plan ID; changing an existing build has no canonical plan.
No upgrade path is defined for this model yet.
Progress is stored in this browser against the exact plan ID; it works offline once the page has been opened.
Following the cut list, cut the floor, walls and roof from 9 mm osb/3 board. Side walls are sloped: 480 mm overall at the front and 440 mm at the rear, so the roof falls to the rear.
Cut a 150 mm × 180 mm opening through the front wall and every inner layer, with the sill 80 mm above the floor so rain and snow stay out. Face the entrance away from the prevailing wind. Cover or sand sharp edges.
Front and rear walls run the full width and the sides fit between them. Join the walls on the floor with corner battens, glue and screws shorter than the wall build-up.
Fit eps foam board boards to the walls, floor and under the roof. Insulation must not stay exposed to the animal.
Cover the insulation with interior plywood lining. Close the edges around the entrance so no foam is visible.
Fix the roof. A roof without covering may only stand under cover.
Coat outside faces and edges with a wood protection finish and let it fully cure before use.
Set the shelter on two battens, about 50 mm above the ground, so the floor does not touch cold, wet ground. Check that it does not rock.
Loosely fill straw to a quarter or half of the interior height. Do not use hay, towels or blankets in an outdoor winter shelter: they absorb moisture and chill.
Set it against a wall or fence, out of the wind, away from roof runoff and roaming dogs. Weight or secure lightweight shelters. Check the spot with the placement checklist.
A source supports a guideline or material value, but it does not confirm this specific model. Container sizes are assumptions and build time is a planning estimate.